Download the product catalogue

7.9MB

Sales
department

Phone

+48 33 846 60 30

Single-core non-sheathed cables with solid conductor and PVC heat-resistant insulation

(for fixed wiring)

Przewód ma certyfikat VDE, znak CE, deklaracje RoHS i REACH
H07V2-U knurled heat-resistant cable
CONSTRUCTION
  1. copper conductor (solid, class 1 acc. to EN/IEC 60228)
    tin-plated or knurled on request
  2. PVC heat-resistant insulation type TI3
    The colours of PVC insulation
    + other colours on the customer’s request
NORMATIVE REFERENCES:
  • EN 50525-2-31
  • PN-87/E-90054*
APPLICATIONS
For fixed installation or use in dry areas. Not suitable for outdoor use, i.e. in the ground or in water. May not be laid in areas exposed to harsh weather conditions.Used inside or outside of luminaires, where there is no danger of contact with hot parts and no exposure to radiation.For making permanent connections in electrotechnical devices and industrial automation.For permanent internal connections, in control and electronic devices, industrial electronics installations, in measuring technology.Suitable for heating and kitchen devices and for use in places with increased temperature (e.g. luminaires), where there is no danger of contact with hot parts and no exposure to direct heat radiation.
PACKING
Cable wound on a reel Cable wound on a spool Cable packed in a cardboard core box Cable packed in a coil
 
TECHNICAL DATA

Max. operating temperature at the conductor:

  • 90°C (H07V2-U)
  • 105°C (DYc)

Rated voltage: 450 / 750 V
Test voltage: 2500 V

* The cables correspond to the withdrawn PN-87/E-90054 standard

The detailed technical specification of the wires, including tables on available cross-sections and their parameters such as approximate cable diameter, weight, nominal insulation thickness, and conductor resistance, can be found in the PDF datasheet of H07V2-U; DYc 450/750V cable

All technical data provided in the cable datasheet and on this page are for informational purposes only and may change without prior notice. They do not constitute an complete list of possible cable variations. We are eager to develop and manufacture additional constructions listed in the standards, as well as custom versions upon request.

Declaration of Performance (DoP):

In accordance with Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011, establishing harmonised conditions for the marketing of construction products, we publish the digitally signed Declaration of Performance (DoP) for the H07V2-U cable in the document 2_CPR_H05V-U_H05V2-U_H07V-U_H07V2-U.pdf. For the DYc 450/750V cable in the document 3_CPR_DY_DYc_DYd.pdf.

VDE Approval Mark:

We also provide the VDE Approval Mark for the H07V2-U cable, available in PDF format on our website or directly on the VDE website. You can verify it under certificate number 40008640 using this link.

Technical details and the offer may change according to market needs and the requirements of applicable standards.